100L -40 Degree Closed Circulation Chiller Ex-Proof Low Temperature Cooling Circulation System
Technical parameters:
Model |
DLSB-100/40 | |
Basic Parameters |
can be equipped with Glass Reactor or Rotary Evaporator | 100L |
Tank Size | 400X200X400mm | |
Tank Capacity(L) | 32L | |
Opening Size(mm) | The closed circulation system no opening size | |
Temp Range(ºC) | RT to -40ºC | |
Environmental Temp | 5-35ºC | |
Relative Humidity | ≤60 | |
Min Temperature | -42ºC | |
Voltage | 240V±10% 60HZ three phase | |
Refrigerating Power(W) | 22050-368 | |
Compressor | 10HP (UL certified) | |
Fan Power | 280WX2pcs | |
Total Power(W) | 8460W | |
Plate-type heat exchanger | Heating exchange area 2.50m2 | |
Meter Range | -150ºC-100ºC | |
Accuracy(ºC) | ±0.5 | |
Sensor | PT100 | |
Circulating Pump Power(w) | 550(UL certified) | |
Lift(m) | 19-22 | |
Flow(L/min) | 40 | |
Pressure(Bar) | 2.2 | |
Basic Configuration | Compressor | Imported Fully Closed Compressor |
Refrigerant | R404A | |
Circulating Pump | Fully Closed No Leakage Special Pump | |
Inlet and outlet Oil Nozzle | 6# or 1.5inch or 1.5inch Tri Clamp( Lower: Inlet, Higher: Outlet ) | |
The method of Controlling Temp | Digital Display | |
Temp Resolution | 1ºC | |
Safety Protection |
Leakage, overload breaker,overload relay keep line, protection timer of a refrigerator, circulating pump thermal protection device, the refrigerator pressure switch, temperature regulating self diagnostic function | |
Cooling Coil | Copper(Nickle Plating) | |
Shell Material | Spraying Paint Anti-Corrosive | |
Overall Dimension(mm) | 1100*800*1300 | |
GW(KG) | 195 | |
Accessories | Inlet and outlet Joints(set) | 1 |
English Manual | 1 | |
Stainless Rod(pc) | 1 | |
Insulation Tube(pc) | 2 | |
Note | we can manufacture ex-proof chiller according to customer's requirements. And equip valves of double inlet and double outlet. |
Package & Delivery:
Factory:
1. Are you the factory?
Yes, we're.
Established in 2008, we manufacture rotary evaporator, jacketed glass reactor, chiller etc.
2. What is the delivery time?
Generally speaking, the delivery time is 7-10 days for regular products. For the customized instrument, about 10~20 days is needed.
3. What's the warranty period? How do you provide this?
One year (12 months).
We have very strict inspection and testing to make sure the instruments which you received are high-quality and reliable.
If there's any problem, we'll provide you the on line solution in 12 hours. If the problem is caused by accessory, we'll provide you the spare parts for free. If the problem is caused by the instrument quality, and cannot be repaired, we'll ship you the new one.