Liquid Sample Total Organic Carbon Analyzer

After-sales Service: Yes(Except The Consumbles)
Warranty: 1 Year
Element: Organic Elemental Analyzer
Analysis: Photoelectric Colorimetry
Display: Digital
Application: Liquid
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
TOC-2000
Performance
Semi-automatic
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Customized
Detector
Ndir
Parameters
Tc, Tic, Toc,Npoc
Digestion Mode
High Temperature Catalytic Oxidation
Gas Requirement
Oxygen More Than 99.995%
Measurement Range
0-30000mg/L
Detection Limit
50μg/L
Transport Package
Wooden Package
Trademark
HEB
Origin
China
Production Capacity
500PCS Per Year

Product Description

                                                                      Liquid sample total organic carbon analyzer
 
Product Description

Introduction:


It can measure the total carbon (TC), total organic carbon (TOC), total inorganic carbon (TIC) and non-purgable total organic carbon (NPOC) in surface water, groundwater, industrial water, domestic sewage, production wastewater, seawater, drinking water and its source water. Widely used in sewage water environment detection, Marine environment detection, industrial production sewage detection, domestic water detection and other fields.

Features:

0-30000 mg/L wide sample testing range
choose the direct method or minusing testing features for different sample testing
high-efficiency catalyst, to ensure the effect of dispelling at the same time, reduce maintenance cost
independent intellectual property rights of circuit system and embedded software collocation of high-performance embedded processors, ensure stable and reliable operation of the system
the operation of the software function is perfect, the use of auxiliary data management database, instrument control, condition monitoring, data processing and data access one-stop operation
machine modular design, provides great convenience for instrument operation and maintenance
self-developed NDIR detector adopts imported light source and detector, the detection sensitivity and stability are good
ensure accurate sample injection system stability, core parts long life, lower maintenance cost
the elaborate design of cleaning and testing process, shorten the testing time, extend the service life of catalyst and combustion tube
functional cracking furnace, PID temperature control technology, ensure the accuracy of temperature stability
the precision air flow control technology, guarantee the accuracy of the carrier gas flow is stable, so as to improve the test precision and stability
the tertiary dehydration technology, the electronic refrigeration dehydration plant collocation can rapidly changing film filter, guarantee the dehydration effect
real-time monitoring instruments each functional unit running condition, more than the critical value immediately report 
optional 20 cups of the automatic sampler, achieve highly automated user experience
optional audit trail version software, accord with the requirement of GMP for computerized system validation, comply with the FDA 21 CFR PART 11 about the integrity of electronic data, electronic signature, the audit tracking requirements
 
Product Parameters

Technical parameters:

 
 Model TOC-2000
 Detector NDIR
 Parameters TC, TIC, TOC,NPOC
 Digestion Mode  High temperature catalytic oxidation
 Operation Mode PC Control
 Application Liquid Sample
 Gas Requirement Oxygen≥99.995%
 Measurement Range 0-30000mg/l
 Detection Limit 50μg/l
 Repeatability  3%
 Maximum Salinity  85g/l
 Power  220±10V,50/60HZ, 1KW
 Size  430*455*440mm
 
Company Profile

 

Liquid Sample Total Organic Carbon AnalyzerLiquid Sample Total Organic Carbon AnalyzerLiquid Sample Total Organic Carbon Analyzer

Our certification:

Liquid Sample Total Organic Carbon Analyzer
Packaging & Shipping

 

Liquid Sample Total Organic Carbon AnalyzerLiquid Sample Total Organic Carbon Analyzer
FAQ

 

1. Are you the factory?

 

Yes, we're.

Established in 2004, we manufacture rotary evaporator,  jacketed glass reactor, chiller etc.

 

2. What is the delivery time?

 

Normally, we have stocks for our hot sale products, the delivery time is about 5-10 days. For the customized instrument, it's about 10~20 days. 

 

3. What's the warranty period? How do you provide this?

 

One year (12 months).

We have very strict inspection, the instruments which you received is high-quality and reliable.

If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.

If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now