Gas Chromatograph (PGC122)

After-sales Service: Yes(Except The Consumbles)
Warranty: 1 Year
Appliance: Food Analysis
Detector: TCD
Certification: CE, ISO
Chromatography Type: Gas Chromatography
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PGC122
Chromatographic Column Type
Capilary Column
Max Temperature
400degree
Transport Package
Plywood Box
Trademark
HEB
Origin
Xian
Production Capacity
100

Product Description


Features:
1. Dual FID detectors, optional PGCl22-TCD, PGCl22-ECD, PGCl22-NPD, PGCl22-FPD, converter, gas sample inlet valve, etc.
2. Dual packed columns, dual samplers and dual gas path system structure, which can effectively restrain base-line fluctuation and drift in real time, suitable for temperature programming analysis.
3. Can work with 3 types of detectors at the same time. With different detector combination in different application, the instrument can support detectors working in either cascade or paralleled connection.
4. Equipped with completed capillary analysis system and independent capillary split sampler, which includes diaphragm cleaning, split flow and auxiliary gas adjustment. It supports capillary split / split less sampler, cold on-column sampler, and 0.53mm large diameter capillary column direct sampler. It's suitable for all kinds of capillary column of various diagrams, speculations, and lengths, and made of glass or flexible silicon glass.
5. The gas path of the instrument adopts high precision scale flow control valve, unloading valve and needle valve. It's easy to adjust flow capability and has better reproducibility and stability.
6. The instrument supports following injection methods:
7. Packed column: on-column sample injection, instantaneous vaporizing sample injection, gas sample injection
8. Capillary column: split injection, split less injection, large diameter column direct injection
9. Newly developed computer aided temperature control system. It can manage the temperature control of six path heating areas at the same time, including column, ion chamber, thermal conductivity detector, capillary column sampler, packed column sampler auxiliary and standby, with high precision (less than ±0.1ºC) and wide range (up to 400ºC), and temperature overload and deviation is less than 2ºCor even lower.
10. The column has five-phase programmed temperature control, and the highest heating rate is up to 40ºC/min.
11. The system has such functions as switch-off protection, temperature limit setup, temperature scanning, rapid automatic cooling, i.e. back opening door, and etc.
12. Open-end computer system can apply RS-232 interface and N-2000 chromatogram workstation to achieve single path communication control and data processing.
13. Large volume full lens stainless column (350mmx280mmx300mm) can support capillary column and dual packed columns at the same time. Inner-placed heating wire structure can facilitate silicon capillary column analysis
Performance Indication:
1. Temperature control range: 7ºC-400ºCof room temperature (increment by 1ºC)
2. Temperature control objects: column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby)
3. Temperature programming phase: five
4. Temperature programming rate: 0.1ºC-40ºC/min(increment by 0.1ºC)
Flame Ionization Detector (FID)
Sensitivity: M≤1x10-11g/s(sample: C16)
Optimal test result: M≤5x10-12g/s
Baseline noise: ≤5x10-14A
Baseline drift: ≤6x10-13A/h
Linear range: ≥10E6
Others:
PGC122 Special Purpose Detectors
PGC122-TCD Thermal Conductivity Detector
Technology Indicators
Sensitivity: S>2500mV ? ml/mg
(Carrier gas H2)
(Sample: n-Hexadecimal)
Baseline noise: ≤20uV
Linear range: ≥104
Features:
Applying rhenium tungsten filament, constant current power supply, different magnifying circuit, and mini-type conductivity
PGC122-ECD Electron Capture Detector
Technology Indicators
Detection limit: Mt≤2x10 -13g/s
(Sample: n-hexagon,-666);
Baseline noise: ≤10uA
Linear range: ≥103
Features
Ni-63 radioactive source applied, up to 350ºCworking temperature, very high sensitivity to
Halogen compounds.
PGC122-NPD Nitrogen and Phosphorous Detector
Technology Indicators
Detection limit:
Nitrogen: Mt≤5x10 -11g/S;
Phosphorus: Mt≤5x10-12g/S
Baseline nose: ≤4x1013A
Linear range: ≥103
Features
High stability rubidium applied, suitable for nitrogen phosphorus compound residue analysis.
PGC122-NPD Nitrogen and Phosphorous Detector
Technology Indicators
Detection limit:
Nitrogen: Mt≤5x10-11g/S;
Phosphorus: Mt≤5x10-12g/S
Baseline nose: ≤4x1013A
Linear range: ≥103
Features
High stability rubidium applied, suitable for nitrogen phosphorus compound residue analysis.
PGC122-FPD Flame Photometric Detector
Technology Indicators
Detection limit:
Nitrogen: Mt≤2x10-11g/S,
phosphor: Mt≤1×10-10g/S
Baseline noise: ≤10uV
Linear range: nitrogen≥103, sulphur≥102
Features
Dual flame structure, light-guide fiber signal trans-mission line applied, greatly reducing the high
temperature affection on electric components, suitable for phosphorus, phosphor trace analysis.
OPTIONAL ACCESSORIES:
TCD
FPD
NPD
N2000 Software with I/O port
OVERALL DIMENSION & WEIGHT:
Shipping package dimension: 1000x720x870mm
Net Weight: 100kg
Gross Weight: 120kg

Package & Delivery:

Gas Chromatograph (PGC122)Gas Chromatograph (PGC122)
Gas Chromatograph (PGC122)
Factory:

Gas Chromatograph (PGC122)Gas Chromatograph (PGC122)
Certification:

Gas Chromatograph (PGC122)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now